Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring, Cables and Non-Metallic Raceways (CAN/ULC S102.4-10)
standard by Underwriters Laboratories of Canada, 07/01/2010
This edition has incorporated requirements for non-metallic raceways.
This test is designed to provide information for evaluating the possibility of fire spreading in a plenum or other space used for environmental air along electrical wires or cables, optical-fiber cables or non-metallic raceways; or the possibility of high smoke levels being developed in the space when wiring or raceways are subject to fire exposure. The test method has been related to the results of tests on cables exposed to fires in simulated plenums.
This test method is used to determine if a cable or non-metallic raceway qualifies for an FT-6classification as specified in CSA C22.2 No. 0.3, Test Methods for Electrical Wires and Cables or CSA C22.2 No. 262, Optical Fiber Cable and Communication Cable Raceway Systems.
This test method is for use in determining values of flame propagation distance and smoke optical density for electrical and optical-fiber cables and non-metallic raceways that are to be installed in ducts, plenums, and other spaces used for environmental air. It is not intended for use with cables enclosed in metallic raceways in those spaces. This method also determines values of flame propagation distance and smoke optical density for electrical and optical-fiber cables with combustible jackets or sheathes, and non-metallic raceways to determine their acceptability for use in buildings of non-combustible construction.
This test method does not cover the construction requirements for cables and non-metallic raceways or their electrical and other performance requirements.
Product Details
- Edition:
- 3
- Published:
- 07/01/2010
- Number of Pages:
- 31
- Note:
- This product is unavailable in Ukraine, Russia, Belarus
Related products
-
ULC 716.3
$50.00$30.00Add to cartStandard for Exterior Insulation and Finish Systems (EIFS) – Design Application (CAN/ULC S716.3-12)
standard by Underwriters Laboratories of Canada, 2019 -
ULC 713.2
$264.00$158.40Add to cartSTANDARD FOR SYSTEM TESTING 2 – ML
standard by Underwriters Laboratories of Canada, 10/01/2011 -
ULC 773
$197.00$118.20Add to cartStandard for Thermal Insulation Terminology (CAN/ULC S773-15)
standard by Underwriters Laboratories of Canada, 07/01/2015 -
ULC 801
$200.00$120.00Add to cartStandard on Electric Utility Workplace Electrical Safety for Generation, Transmission and Distribution (CAN/ULC S801-14)
standard by Underwriters Laboratories of Canada, 2014
ULC 102.4
$205.00 $123.00
Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring, Cables and Non-Metallic Raceways
standard by Underwriters Laboratories of Canada, 09/01/2017
ULC 102.4 – Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring, Cables and Non-Metallic Raceways
Product Details
- Edition:
- 4
- Published:
- 09/01/2017
- Note:
- This product is unavailable in Ukraine, Russia, Belarus
Related products
-
ULC 718
$50.00$30.00Add to cartSite Quality Assurance Program For Spray Polyurethane Foam
standard by Underwriters Laboratories of Canada, 2018 -
ULC 741
$209.00$125.40Add to cartStandard for Air Barrier Materials – Specification (CAN/ULC S741-08)
standard by Underwriters Laboratories of Canada, 12/01/2008 -
ULC 8752
$264.00$158.40Add to cartStandard for Organic Light Emitting Diode (LED) Panels (CAN/ULC S8752)
standard by Underwriters Laboratories of Canada, 04/01/2012 -
ULC 743.2
$170.00$102.00Add to cartSTANDARD FOR THERMAL INSULATION – LOW PRESSURE APPLIED TWO COMPONENT SPRAY POLYURETHANE FOAM, PART 2: INSTALLATION