CGA V-1 – Standard for Compressed Gas Cylinder Outlet and Inlet Connections
CGA’s Cylinder Valve Committee, applying the experience and knowledge of gas producers, valve manufacturers, military services, federal agencies, and gas users, established detailed dimensions for the manufacture of new cylinder valve outlet and inlet connections.
The scope of this standard is to provide connections that minimize the possibility of hazardous misconnections. This standard is based on a coordinated plan for the inclusion of future connections as they are required on cylinders that are not permanently manifolded during transport and use. Standard outlet connections for respective gases are fully defined and complete in themselves. These outlet connections are designed to minimize the possibility of hazardous misconnections.
Product Details
- Edition:
- 15th
- Published:
- 01/01/2021
- Number of Pages:
- 180
- File Size:
- 1 file , 8.5 MB
- Note:
- This product is unavailable in Russia, Ukraine, Belarus
Related products
-
CGA V-22
$9.00$5.40Add to cartGuidelines to Address Potential Hazards of Quick Release Cylinder Valves Used in Firefighting Systems (Formerly SB-39)
Published by Publication Date Number of Pages CGA 06/16/2020 10 -
CGA V-15
$21.00$12.60Add to cartUse of Residual Pressure Valves
Published by Publication Date Number of Pages CGA 05/01/2016 12 -
CGA V-5
$65.00$39.00Add to cartStandard for Diameter Index Safety System (Noninterchangeable Low Pressure Connections for Medical Gas Applications)
Published by Publication Date Number of Pages CGA 05/24/2019 15 -
CGA V-17 (R2022)
$16.00$9.60Add to cartGuideline for Handling and Use of CGA 630/710 Series Ultra High Integrity Service Connections (Formerly TB-9)
Published by Publication Date Number of Pages CGA 09/27/2016 10
CGA V-1
$384.00 $230.40
Standard for Compressed Gas Cylinder Outlet and Inlet Connections (Includes 9/13/2019 Correction)
standard by Compressed Gas Association, 09/13/2019
Detailed dimension drawings of 115 valve outlet connections for nearly 270 different products. Covers threaded connections, yoke outlets, and the Pin Index Safety System for flush outlet valves of the yoke type used for medical gases. The scope of CGA V-1 is to provide connections that minimize the possibility of hazardous misconnections. This standard is based on a coordinated plan for the inclusion of future connections as they are required on cylinders that are not permanently manifolded during transport and use. Standard outlet connections for respective gases are fully defined and complete in themselves. The outlet connections are designed to minimize the possibility of hazardous misconnections.
Product Details
- Edition:
- 14th
- Published:
- 09/13/2019
- Number of Pages:
- 168
- File Size:
- 1 file , 5 MB
- Note:
- This product is unavailable in Russia, Ukraine, Belarus
Related products
-
CGA V-1
$414.00$248.40Add to cartStandard for Compressed Gas Cylinder Outlet and Inlet Connections
Published by Publication Date Number of Pages CGA 01/01/2021 180 -
CGA V-16
$16.00$9.60Add to cartGuideline for the Application of CGA Publications to Cylinder Valves
Published by Publication Date Number of Pages CGA 09/01/2016 12 -
CGA TB-31
$15.00$9.00Add to cartResidual Pressure Valve (RPV) Fill Adapters
Published by Publication Date Number of Pages CGA 11/01/2013 3 -
CGA TR-5
$9.00$5.40Add to cartTechnical Report on Nitrosamine Impurities in Nitrous Oxide and other Medical Gases
Published by Publication Date Number of Pages CGA 11/23/2021 8
CGA V-1
$367.00 $220.20
Standard for Compressed Gas Cylinder Outlet and Inlet Connections
standard by Compressed Gas Association, 05/01/2013
Detailed dimension drawings of 115 valve outlet connections for nearly 270 different products. Covers threaded connections, yoke outlets, and the Pin Index Safety System for flush outlet valves of the yoke type used for medical gases. The scope of this standard is to provide connections that minimize the possibility of hazardous misconnections. This standard is based on a coordinated plan for the inclusion of future connections as they are required on cylinders that are not permanently manifolded during transport and use. Standard outlet connections for respective gases are fully defined and complete in themselves. The outlet connections are designed to minimize the possibility of hazardous misconnections.
Product Details
- Edition:
- 13th
- Published:
- 05/01/2013
- Number of Pages:
- 162
- File Size:
- 1 file , 4.5 MB
- Note:
- This product is unavailable in Russia, Ukraine, Belarus
Related products
-
CGA V-19
$16.00$9.60Add to cartMarking Requirements to Mitigate Potential Cylinder and Cylinder Valve Thread Mismatches (Formerly TB-16)
Published by Publication Date Number of Pages CGA 03/01/2018 12 -
CGA TB-3 (R2014)
$15.00$9.00Add to cartOxy-Fuel Hose Line Flashback Arrestors
Published by Publication Date Number of Pages CGA 08/27/2008 1 -
CGA V-12
$13.00$7.80Add to cartLeak detection fluids use with gas cylinder packages, Third Edition
Published by Publication Date Number of Pages CGA 06/16/2020 10 -
CGA V-7.1
$60.00$36.00Add to cartStandard Method for Determining Cylinder Valve Outlet Connections for Medical Gases, Second Edition
Published by Publication Date Number of Pages CGA 01/01/2021 22