UOP 303 – Impurities in Catalysts by ICP-OES
This method is for determining trace metal elements in fresh, regenerated and spent alumina-, silica- or silica/alumina-based catalysts by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES). Fe, Ni, V, Ca, Mg, Mn, Cr, Sn, Cu, Zn, Ti, Pb, Na, Mo, Co and Si are determined quantitatively on catalysts. Si is not determined when it is a component of the catalyst base. Other elements can be added if required, however, Ba and Hg cannot be determined. In addition, As and P are determined on regenerated or spent alumina-based catalyst. The majority of the specified elements can be determined within the concentration range of 0.005 to 2.0 mass-%. Specific concentration ranges for the elements determined are listed in Table 1.
This method is not applicable to noble metals and modifiers on catalysts. Those elements can be determined by UOP Method 873.
This method cannot be used for determining impurities in alpha-alumina catalyst.
Product Details
- Published:
- 05/31/2007
- Number of Pages:
- 12
- File Size:
- 1 file , 110 KB
Related products
-
UOP 987
$240.00$144.00Add to cartLow Trace Sulfur in Liquid Hydrocarbons by Oxidative Combustion with Ultraviolet Fluorescence Detection
Published by Publication Date Number of Pages UOP 01/01/2015 13 -
UOP 980
$287.00$172.20Add to cartC5 and Lower Boiling Dienes, Olefins, and Paraffins in Naphthas by GC
Published by Publication Date Number of Pages UOP 02/23/2007 15 -
UOP 969
$287.00$172.20Add to cartPermanganate Fading for Acetic Acid
Published by Publication Date Number of Pages UOP 01/01/2000 3 -
UOP 990
$240.00$144.00Add to cartOrganic Analysis of Distillate by Comprehensive Two-Dimensional Gas Chromatography with Flame Ionization Detection
Published by Publication Date Number of Pages UOP 07/11/2011 48