Category
Recently Viewed Products
-
AWS A1.1
$79.00$47.40 -
IES LM-48
$50.00$30.00 -
BS 1000M:SUPPLEMENT NO.3
$177.80$106.68 -
ESD STM11.13
$169.00$101.40 -
ESD JS-001
$135.00$81.00
ICEA S-113-684 – Performance Based Standard for Electric Utility Extruded Dielectric Shielded Power Cables Rated 5 Through 46 KV
This standard provides the basis for designing non-traditional shielded power cables that will be rated 5 to 46 kV and be used for the transmission and distribution of electrical energy. These non-traditional cables will normally have overall diameters that are less than the diameters of what are considered traditional shielded power cables as specified in ICEA Standards S-94-649 and S-97-682. This standard is not intended to promote standardization of cable component thicknesses or dimensions. The smaller overall diameters are accomplished by reducing the wall thicknesses of the various polymer and metallic layers of the cable. As the polymer layer thicknesses are reduced, the electrical stress in the cable may increase. Manufacturers will design their cables based on what they have determined to be the maximum acceptable electrical stress levels that will not adversely affect their cable?s performance. Since performance based designs can vary from manufacturer to manufacturer, the user of this standard must evaluate non-traditional cable designs very carefully. Additionally, the user of this standard must consider the impact performance based cable designs will have on cable accessories.
Note: See Appendix K for cable insulations qualification requirements or cable design features appropriate for submerged applications.
Product Details
- Published:
- 07/07/2016
- ISBN(s):
- 112
- ANSI:
- ANSI Approved
- File Size:
- 1 file , 840 KB
- Note:
- This product is unavailable in Ukraine, Russia, Belarus
Related products
-
ICEA S-83-596
$170.00$102.00Add to cartStandard for Indoor Optical Cable
Published by Publication Date Number of Pages IECA 02/02/2022 53 -
ICEA S-81-570
$137.00$82.20Add to cartStandard for 600 Volt Rated Cables with Ruggedized Design for Direct Burial Installations as Single Conductors or Assemblies of Single Conductors
Published by Publication Date Number of Pages IECA 11/05/2019 41 -
ICEA S-58-67
$93.00$55.80Add to cartStandard for Control, Instrumentation and Thermocouple Extension Conductor Identification
Published by Publication Date Number of Pages IECA 01/28/2014 17 -
ICEA S-90-661
$147.00$88.20Add to cartSTANDARD FOR CATEGORY 3 AND 5E INDIVIDUALLY UNSHIELDED TWISTED PAIRS, INDOOR CABLES (WITH OR WITHOUT AN OVERALL SHIELD) FOR USE IN GENERAL PURPOSE AND LAN COMMUNICATION WIRING SYSTEMS
Published by Publication Date Number of Pages IECA 08/10/2021 41