ICEA P-117-734 – Ampacities For Single-Conductor Solid Dielectric Power Cable 15 kV Through 35 kV
This publication presents calculated ampacities for 15 through 35 kV, single-conductor solid-dielectric insulated power cables with multiple bonded and grounded shields, copper or aluminum conductors, single or three phase operation, spaced or trefoil configurations, single or double circuits, directly buried or in buried ducts. Ampacities are given for three or four different shield resistances for each conductor size.
The ampacity calculations provided in this guide have been performed with the software program CYMCAP Ver. 5.3 Rev 2 from CYME International. The methodology used in the calculations is based on Neher-McGrath [6] and the international standard IEC 60287 [9]. Recognizing that both this IEC standard and the CYMCAP modeling program will undergo changes over time, the user may not get repeatable results with CYMCAP in the future from those shown in this guide. To minimize these potential differences, the values shown have been rounded to the nearest 5 amps and should not be considered as exact since it is generally accepted that there are many variables that influence the actual ampacity of an installation even beyond those of the calculation method. Additions to this document made in 2021 to add ampacities for 1250 kcmil and 1500 kcmil were made with CYMCAP Ver. 8.0 Rev 2.
Product Details
- Published:
- 07/06/2022
- ANSI:
- ANSI Approved
- Number of Pages:
- 126
- File Size:
- 1 file , 4.2 MB
- Note:
- This product is unavailable in Ukraine, Russia, Belarus
Related products
-
ICEA T-25-425
$83.00$49.80Add to cartGUIDE FOR ESTABLISHING STABILITY OF VOLUME RESISTIVITY FOR SEMICONDUCTING POLYMERIC COMPONENTS OF POWER CABLES
Published by Publication Date Number of Pages IECA 09/16/2015 13 -
ICEA T-22-294
$80.00$48.00Add to cartICEA TEST PROCEDURES FOR EXTENDED TIME-TESTING OF WIRE and CABLE INSULATIONS FOR SERVICE IN WET LOCATIONS
Published by Publication Date Number of Pages IECA 03/14/2016 8 -
ICEA S-83-596
$170.00$102.00Add to cartStandard for Indoor Optical Cable
Published by Publication Date Number of Pages IECA 02/02/2022 53 -
ICEA S-81-570
$137.00$82.20Add to cartStandard for 600 Volt Rated Cables with Ruggedized Design for Direct Burial Installations as Single Conductors or Assemblies of Single Conductors
Published by Publication Date Number of Pages IECA 11/05/2019 41