Category
Recently Viewed Products
-
CLSI VET01S
$180.00$108.00 -
CISPR CISPR/TR 16-4-1 Ed. 2.0 en
$375.00$225.00 -
AS/NZS 1056.4
$68.45$41.08 -
ASA S2.32
$110.00$66.00 -
DIN 10111
$49.50$29.70
CISPR CISPR/TR 16-4-1 Ed. 2.0 en
$375.00 $225.00
Specification for radio disturbance and immunity measuring apparatus and methods – Part 4-1: Uncertainties, statistics and limit modelling – Uncertainties in standardized EMC tests
Published by | Publication Date | Number of Pages |
CISPR | 02/23/2009 | 117 |
CISPR CISPR/TR 16-4-1 Ed. 2.0 en – Specification for radio disturbance and immunity measuring apparatus and methods – Part 4-1: Uncertainties, statistics and limit modelling – Uncertainties in standardized EMC tests
CISPR/TR 16-4-1:2009 gives guidance on the treatment of uncertainties to those who are involved in the development or modification of CISPR electromagnetic compatibility (EMC) standards. In addition, this part provides useful background information for those who apply the standards and the uncertainty aspects in practice. The objectives of this part are to:
a) identify the parameters or sources governing the uncertainty associated with the statement that a given product complies with the requirement specified in a CISPR recommendation. This uncertainty will be called “standards compliance uncertainty”;
b) give guidance on the estimation of the magnitude of the standards compliance uncertainty;
c) give guidance for the implementation of the standards compliance uncertainty into the compliance criterion of a CISPR standardised compliance test.
As such, this part can be considered as a handbook that can be used by standards writers to incorporate and harmonise uncertainty considerations in existing and future CISPR standards. This part also gives guidance to regulatory authorities, accreditation bodies and test engineers to judge the performance quality of an EMC test-laboratory carrying out CISPR standardised compliance tests. The uncertainty considerations given in this part can also be used as guidance when comparing test results (and their uncertainties) obtained by using different alternative test methods. The uncertainty of a compliance test also relates to the probability of occurrence of an electromagnetic interference (EMI) problem in practice. This aspect is recognized and introduced briefly in this part. However, the problem of relating uncertainties of a compliance test to the occurrence of EMI in practice is not considered within the scope of this part. The scope of this part is limited to all the relevant uncertainty considerations of a standardized EMC compliance test. This second edition of CISPR 16-4-1 cancels and replaces the first edition published in 2003, and its Amendments 1 (2004) and 2 (2007). It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. The provisions available for application of uncertainties in the determination of the compliance criterion are explained more generally and a procedure is added for re-testing an approved EUT by another test house.
Product Details
- Edition:
- 2.0
- Published:
- 02/23/2009
- Number of Pages:
- 117
- File Size:
- 1 file , 1.8 MB
- Note:
- This product is unavailable in Ukraine, Russia, Belarus
Related products
-
CISPR 19 Ed. 1.0 b
$26.00$15.60Add to cartGuidance on the use of the substitution method for measurements of radiation from microwave ovens for frequencies above 1 GHz
Published by Publication Date Number of Pages CISPR 01/01/1983 9 -
CISPR 21 Ed. 2.0 b
$38.00$22.80Add to cartInterference to mobile radiocommunications in the presence of impulsive noise – Methods of judging degradation and measures to improve performance
Published by Publication Date Number of Pages CISPR 10/08/1999 15 -
CISPR 17 Ed. 2.0 b
$392.00$235.20Add to cartMethods of measurement of the suppression characteristics of passive EMC filtering devices
Published by Publication Date Number of Pages CISPR 06/10/2011 132 -
CISPR CISPR/TR 16-2-5 Ed. 1.0 en
$90.09$54.06Add to cartSpecification for radio disturbance and immunity measuring apparatus and methods – Part 2-5: In situ measurements for disturbing emissions produced by physically large equipment
Published by Publication Date Number of Pages CISPR 07/09/2008 15